Repository logo
Research Outputs
Projects
People
Statistics
  1. Home
  2. HSG CRIS
  3. HSG Publications
  4. Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device
Details

Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device

Journal
Journal of Analytical Toxicology
Type
journal article
Date Issued
2023-02
Author(s)
Stöth, Frederike
;
Koch, Kevin  
;
Bantle, Matthias
;
Pütz, Philipp
;
Wortmann, Felix  
;
Weinmann, Wolfgang
DOI
10.1093/jat/bkad009
Abstract
Direct alcohol biomarkers are of growing interest for the assessment of alcohol consumption, with particular interest in phosphatidylethanol (PEth) in recent years. PEth is only formed when alcohol is present in the body. However, there is no statement about how much the PEth concentration increases after single moderate alcohol consumption. This study was conducted to determine the increase in PEth concentrations after a single drinking event. Additionally, a new volumetric sampling device (volumetric dried blood spot cards (DBSV)) was evaluated, which was designed to simplify further sampling processes and to allow for easy self-sampling. Dried blood samples from 31 volunteers were collected before and after single alcohol consumption with a mean maximum breath alcohol concentration of 0.4 mg/L (range: 0.30–0.55 mg/L). PEth concentrations were determined after automated extraction by liquid chromatography-tandem mass spectrometry. PEth 16:0/18:1 and PEth 16:0/18:2 concentrations increased to an average of 45 ng/mL each in patients starting below 20 ng/mL (range: 25.0–57.0 ng/mL for PEth 16:0/18:1; range 26.8–62.3 ng/mL for PEth 16:0/18:2). PEth concentrations in patients starting above 20 ng/mL increased by a mean of 30 ng/mL (range: 6.2–71.3 ng/mL for PEth 16:0/18:1; range 8.8–65.3 ng/mL for PEth 16:0/18:2). In addition, the comparison of the new sampling device DBSV with a standard filter paper card (with volumetrically applied 20 µL of blood samples) yielded a close agreement for the determined PEth concentrations in 24 forensic samples and three external controls. Therefore, the sampling device DBSV proved to be suitable for the determination of PEth concentrations in blood.
Language
English
HSG Classification
contribution to scientific community
HSG Profile Area
None
Refereed
Yes
Pages
7
Official URL
https://doi.org/10.1093/jat/bkad009
URL
https://www.alexandria.unisg.ch/handle/20.500.14171/107775
Subject(s)

other research area

Division(s)

ITEM - Institute of T...

IWI - Institute of In...

Eprints ID
269424
File(s)
Thumbnail Image
Name

Increase of PEth after Single Consumption.pdf

Size

948.88 KB

Format

Adobe PDF

Checksum (MD5)

7375bf68c9ab629a3271ce809bcb7fb7

Support
HSG researchers can find instructions here for adding or importing publications (DOI, ORCID). Please send questions to alexandria@unisg.ch

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify